Traditional Culture Encyclopedia - Hotel accommodation - How to calculate the water consumption of hotel hot water project

How to calculate the water consumption of hotel hot water project

Many hotels are now using solar water heating projects, and customers hope to strike a balance in terms of economy, environmental protection, investment costs, etc. Let’s take a look at the water consumption analysis of hot water projects based on this With the customer's actual situation as the background, we systematically discuss the selection of hotel central hot water engineering solutions. First of all, whether we use a traditional electric boiler, AO Smith gas water heater, Midea air energy central water heater or other brands of air source heat pump water heaters, the first step we need to confirm is the daily hot water usage of the project. . According to national standards and industry experience, the hot water consumption of economical hotels is calculated based on 100L/person/bed. Therefore, the maximum daily hot water consumption of a 60-room hotel is 60*2*100=12000L=12 tons. Based on the actual situation of the customer, the estimated occupancy rate is 90. Therefore, the daily consumption of central hot water in the hotel is approximately 12*0.9=10.8 tons, totaling 11 tons. After determining the water consumption, we then decide what type of central hot water engineering host equipment to choose. This can be determined according to the actual situation