Traditional Culture Encyclopedia - Hotel accommodation - What are the standard specifications for the design of three-star hotels?
What are the standard specifications for the design of three-star hotels?
Fire exits (cargo exits) should be separated from the main exits. C) Independent passage of stairs; D) layout of large space; E) scattered eaves-prevent rainwater from flowing to the floor f) internal traffic g) proportion of functional areas h) area relationship between computer room and guest room i) layout and area of bathroom j) guest room doors should be staggered II. Hotel structure 1, design problems: 1), column spacing and material modulus; 2), the relationship between the guest room area and the column spacing 3), the size of the motor shaft 4), the consideration of shaft rejection 5), the height of the floor is 2.7m and 3.0m 6), the layout of the pipe shaft is separated, and there is a certain space 7), the bearing capacity of the movable partition wall of the multi-function hall 8), the height requirement of the elevator door exit 9), the net size of the building is required to be star 10), and the kitchen floor does not settle. When installing vibration equipment, consider the impact on the service area. 3. Hotel water, electricity and air conditioning-the secondary design is generally water and electricity decoration design. It is suggested that relevant professional design institutes should be invited to carry out 1. Water supply for the hotel: purification, softening, disinfection, pressure stabilization and direct drinking water 1) are required. The material of pipe network in the hotel a) copper (including water supply supervisor) is preferred. b) horizontal pipes should be equipped with compensation devices every 70 meters (reducing water hammer). c) It is best to have two water supply designs (ring network is recommended). Avoid diseases such as hypertension and kidney calculi. e) The second consideration is to choose PPR pipes (high utilization rate and expensive joints). f) It is recommended not to use cast iron pipes when launching. G) The water supply system must be designed with a reasonable voltage regulator; H) It is recommended to adopt reclaimed water treatment system-secondary utilization of water: watering flowers and flushing toilets i) It is recommended not to design floor drains in guest rooms and bathrooms (to prevent odor from entering the room) 2) Precautions: 2. An electrical part 650. 2) designing a standby generator set; 3) Installation position of the control switchboard in the guest room-Requirements: focus on convenience for guests, followed by convenience for maintenance (should be considered) 4). Selection of switch panel in guest room-requirements: labor-saving, good feel, simple and bright, preferably two (not more) 5). The guest room power supply is not centralized. A) mobile phone charging (including computer surfing) socket b) refrigerator socket c) air conditioning fan coil power supply 6). Reasonable layout of cleaning (sweeping) power supply 7). The design height of available power supply-requirements: it is better to exceed the desktop 10 to 15 cm) and the distance between wiring and weak current pipes-according to the current technical means, there is no need to deliberately require 9), the relationship between equipment starting current and transformer selection -80% of transformers meet the highest configuration efficiency 10), and the reasonable selection of inverter equipment-effective energy saving is considered. Fourth, the second design of the hotel 1, the theme of the second design is determined: 1), emphasizing the cultural connotation; Third, consider local characteristics; Melody expression-design should highlight the central theme from beginning to end; Fourth, design works should be judged by future generations; Second, the structural design 1), the material of structural design is secondary. Contents to be considered: 2) Embedded parts in secondary structure design; 3) One-way access to the kitchen-separating the guest access from the service access to avoid contact between the service personnel and the guests-the distance between the service access and the kitchen should not be too long-the design should be at the same level (production and consumption) as far as possible; 3) Redesign of public * * * area: 1), and reasonable buffers of auxiliary functional areas have the same functions and relationships. 2), the guest corridor-not less than 1.8 meters, the doors between pipes should be paid attention to 3), the auxiliary passage (service passage)-separated from the guest passage 4), the bathroom in public areas-the bathroom area design in different areas should be different 5), the waterscape design-try not to use a) to increase the humidity in the lobby area-right.
- Previous article:How about Xi'an Yuegang Hotel Management Co., Ltd.?
- Next article:Basic principles of hotel industry.
- Related articles
- Where can I find a machine to sell jiaozi with chaotic noodles in Qingdao?
- Which is better, Buick New LaCrosse 2.0t or 2.4L?
- What are the shortcomings of the hotel¡¯s service?
- Zhengzhou guoling hot spring resort hotel-multi-function hall is not in the restricted area.
- Sofitel's Sofitel is in China
- How far is Chengyang Railway Station from Danube Hotel?
- How to arrange the trip of Shapotou in Ningxia?
- The 2018 Shaanxi Tourism Annual Pass includes a list of scenic spots in Chongqing, Yunnan and Guizhou + contact numbers
- Will the hotel check in?
- A poem describing a breakthrough