Question 1: new fire regulations, does the toilet need to be sprayed? This is determined according to the nature of the building and the area of the bathroom. High-rise buildings of Class II buildings, toilets of Class II complex buildings and Class I buildings with an area of more than 5 square meters need to be set up.

Question 2: Does the bathroom need a shower? My family has a shower, because the bathroom space is limited and there is no bathtub.

Question 3: The area requirement of bathroom shower refers to the building area of a bathroom.

Question 4: For high-rise buildings and their skirt buildings with a building height exceeding 100m, automatic sprinkler systems should be installed except swimming pools, skating rinks, bathrooms with a building area of less than 5.00m2, residential indoor rooms with Class A fire doors without central air conditioning, and parts unsuitable for water fire fighting.

7.6.2 Except for swimming pools, skating rinks, bathrooms with a building area of less than 5.00m2, ordinary houses, indoor rooms of houses with central air conditioning, and parts not suitable for water fire fighting, automatic sprinkler systems shall be set up for high-rise buildings with a building height of 100m and their podium.

There are no requirements for low-rise buildings.

Question 5: Is the fire-fighting acceptance bathroom equipped with sprinkler heads, articles 7.6. 1 and 7.6.2? If it is less than 5O, the bathroom may not be equipped with spray; If it exceeds 5O, it needs to be equipped with spray.

Question 6: Is it necessary to set up a shower distribution room, an electric shaft, a water pipe shaft with an area of less than 5 square meters and a public shower room in the public bathroom of a multi-storey hotel?

Shower area, elevator room and other rooms protected by fixed automatic fire extinguishing system;

In addition to the shower room, the use area does not exceed five square meters, and there is no need for spraying.

Question 7: Is the shower pipe allowed to go from the bathroom? Yes, you can. The main pipe can be branched, and the end of the general spray pipe will also be on the drainage mop pool in the bathroom.

Question 8: Should the public toilets in high-rise office buildings be sprayed? In the past, toilets below 5 square meters with a height of 100 meters did not need spraying. However, the new rules came out. According to the regulations, it is not pointed out that the bathroom does not need spraying. Therefore, according to this, the toilets of a class of high-rise buildings should be sprayed now.

Question 9: Do rooms and bathrooms in five-star hotels need to be equipped with fire sprinklers? Strictly speaking, first of all, although it is a five-star hotel, is it a high-rise building? It is not a high-rise building, and there is generally no shower in the bathroom. Followed by high-rise buildings, then according to 7.6. 1 and 7.6.2 of the high code, there is no need to set a shower in the bathroom smaller than 5O, and it is necessary to set a shower in the bathroom larger than 5O.

Question 10: Is it necessary to install a fire sprinkler in the bathroom? It's not necessary. Shower rooms are full of places with high fire protection requirements, which are generally large spaces. Have a plenty of aisle to do. Bathrooms don't do this.