Traditional Culture Encyclopedia - Hotel accommodation - What are the requirements for the structure of a light well?

What are the requirements for the structure of a light well?

(1) There are three ways to arrange the top of the lighting well: Jinxiushanhe lighting well is covered with glass, aluminum alloy grille is used, Vanke Qinglinjing lighting well is covered with aluminum alloy grille, and wood is used as grille Vanke The light well in the hall is covered with a wooden grille. If it is to be used in the basement, it will be covered with glass, so that it can only provide lighting and give up the ventilation function.

(2) Drainage should be done well at the bottom of the lighting well. If the lighting well does not have a roof, drainage must be arranged to avoid obstruction caused by poor drainage due to heavy rain. It can be seen at the site of each villa that it is generally There is a drainage point at each end of the light well.

(3) Lighting well size: Lighting wells have various sizes depending on where they are set up. Generally speaking, larger sizes have better lighting effects. During this survey, it was found that the light wells of Jinxiu Shanhe and DoubleTree Villas are the narrowest, both are set up for bathroom lighting, only about 30 centimeters, while the light wells of Vanke series products are about 1.5 meters wide, in the basement. Shown as a place that can be accessed. The widest lighting well is excavated on three sides of the single-family villa in Zhaohua Xicheng. It can be concluded that as long as there is space, sufficient lighting can be provided.

(4) Lighting Well Treatment The location and size of the lighting wells in some villas. Qinglin Path is 280 square meters in a double unit. There are two lighting wells, one outside the living room 2.5 × 1.6 and one in the courtyard 2.5 × 1.5 Qinglin There are two light wells in a row with a diameter of 220 square meters. One is 3.3 × 1.5 outside the living room and the other is 2.5 × 1.5 in the courtyard. There are two light wells in a row with a diameter of 280 square meters in Qinglin Trail. One is 3.9 × 1.5 outside the living room and the other is 3.9 × 1.5 in the courtyard. Vanke Tangyue 340 square meters row of three light wells, one in the foyer 3.9 × 1.5, two in the courtyard 4.1 × 1.5 4× 1.3 Shuixieshan 345 square meters in a row of two light wells, one next to the kitchen 4.7 4.2× 1.2 Shuixieshan 234 square meters with a light well next to the kitchen 3× 1.8.

(5) Side lighting In the semi-basement of the villa, there are many open windows on the sides as auxiliary lighting, which is very effective. For example, the side lighting windows in the semi-basement of Parkland provide good sunlight to the underground bathrooms. The exterior and interior effects of basement lighting windows are also found in the stairwells of most villas. Many forms of windows are installed on the facades of most villas. Together with the lighting at the top of the stairs, the stairwells of the villas can also be sunny.