What are the special requirements for "kitchen" in the fire code?

The kitchen needs fire doors. Fire doors are an important part of fire-fighting equipment, which can prevent the spread of fire and smoke in case of fire, ensure the safe evacuation of personnel, and have corresponding standards for installation and use.

1, Code for Fire Protection Design of High-rise Civil Buildings (GB50045-95) stipulates that fire doors should be horizontal doors that open in the evacuation direction, and can be manually opened from either side after closing.

2. According to Code for Fire Protection Design of Buildings (GB500 16-2006), the evacuation doors of civil buildings and factories should be opened in the evacuation direction. Except for Class A and Class B production rooms, when the number of people in the room does not exceed 60 and the average evacuation number per door does not exceed 30, the direction of opening the door is not restricted.

Expand the data 1, strictly implement the management regulations for liquefied gas stoves and diesel stoves, and ensure that the stoves are in good use.

2. Gas cylinders shall not be stored in inhabited rooms or crowded places, and the distance between gas cylinders and stoves shall not be less than1.5m. ..

3, often check the various parts of the furnace, found that the valve blockage, failure, hose aging and other issues, to immediately stop repair. If you find the smell of liquefied petroleum gas in the room, you should immediately turn off the stove switch and angle valve, cut off the gas source, open the window in time, and it is forbidden to smoke, ignite or start the switch of surrounding electrical appliances. The dew point can be checked with soapy water, and it is forbidden to try to leak with open flame. When replacing liquefied gas tanks, foam water should be used for safety inspection in order to eliminate potential safety hazards in time.

4. When the stove is ignited, first open the angle valve, then strike a match, and then turn on the stove switch. If it is not ignited, turn off the stove switch and re-ignite after the oil and gas diffuse.

5. Turn off the switch and angle valve of the cooker after fire to avoid gas overflow caused by aging, cracking, falling off or being bitten by rats. If there is any problem, it should be repaired in time.