Traditional Culture Encyclopedia - Hotel accommodation - How to decorate weak wires?
How to decorate weak wires?
1. Basis for determining points: Mark the cassette position of each point with a pencil, ruler or Amodou according to the home wiring design drawing and the point map on the wall.
2. Determination of cassette height: except for special requirements, the cassette height should be the same as that of the original high-voltage socket, and the height of the background music tuning switch should be the same as that of the original high-voltage switch. If there are multiple cassettes, the distance between cassettes should be at least10 mm.
3, determine the location of the junction box:
1 > embedded: the width and height of the adopted weak current junction box are increased by 10mm respectively, and the depth direction is decreased by 10mm.
2 > external type: mark the position of the fixing hole according to the model size of the product used.
3 > Built-in: Determine the height of the pipeline entering the products used.
Second, slotting
1. Determine the slotting route according to the following principles:
1 > shortest path principle;
2 > it does not destroy the original high-pressure principle;
3 > Don't destroy the waterproof principle.
2. Determine the slot width: determine the number of PVC pipes according to the number of signal lines, and then determine the slot width.
3. Determine the grooving depth: if 16mm PVC pipe is selected, the grooving depth is 20mm;; If 20mm PVC pipe is selected, the grooving depth is 25mm.
4. Appearance requirements of trunking: horizontal and vertical, with the same size.
5. Measurement of trunking: The trunking of cassette and distribution box shall be calculated separately. All trunking shall be measured from the beginning to the end of trunking. If the width of trunking exceeds 80mm, it shall be calculated according to the length of double trunking. 3. wiring.
1, to ensure smooth cable:
1 > test of network cable and telephone line: make crystal heads respectively and test the connection and disconnection with network tester;
2 > Test of cable TV cable, audio and video cable and audio cable: use multimeter to test on and off respectively;
3 > Other cables: test the connection and disconnection with corresponding professional instruments.
2, determine the line length of each point:
1 > measure the length from the junction box slot to each point;
2 > Plus the length of redundant wires and distribution box slots at each point: the length of outgoing wires at each point is 200mm-300mm;; Inside the distribution box: 500mm background music exit: 1.5m-2m.
3. Label determination: After cutting all kinds of cables according to a certain length, put labels on both ends of the line, indicating: weak current type-room-serial number.
4. Determine the number of wires in the pipe: the cross-sectional area of wires in the pipe shall not exceed 80% of the cross-sectional area of the pipe.
Fourth, seal the groove.
1. Fix the cassette: except for the cassette in the kitchen and bathroom, which should protrude 20mm from the wall, other cassettes should be flush with the wall. When several boxes are together, they are required to be on the same level.
2, fixed PVC pipe:
1 > PVC pipes on the ground must be fixed every one meter;
2 > geosyncline PVC pipes must be fixed every two meters;
3 > PVC pipes in the wall groove must be fixed every one meter.
3. Groove sealing: The wall and ground after groove sealing shall not be higher than the plane.
4. Clean up the construction site: after the trench is closed, remove the garbage and clean up the construction site.
1) Each weak current subsystem adopts star structure.
2) 2~3 inlet pipes are introduced into the household information access box from the outside. The outlet conduit extends from the home information box to each indoor information socket. The concealed pipes (threading pipes) laid shall be steel pipes or flame-retardant rigid PVC pipes (rigid PVC pipes).
3) The pipe diameter utilization rate of straight pipes should be 50%~60%, and that of bent pipes should be 40%~50%.
4) When there are local interference sources on the routing road and the minimum clear distance cannot be met, steel pipes should be adopted.
5) When the straight laying length of concealed pipes exceeds 30m, a box should be installed in the middle.
6) When the concealed pipe must be bent and laid, its routing length should be ≤ 15m, and there should be no S-bend in this section. When bending continuously for more than 2 times, the junction box shall be installed.
7) The bending radius of the concealed pipe shall not be less than 6~ 10 times of the outside diameter of the pipe.
8) There shall be no cable connector in the concealed pipe hole.
- Related articles
- What to buy in Macau? Is shopping in Macau cheaper than in Hong Kong?
- Let your rural Chinese wedding not lose the city.
- There is a kind of glass that becomes opaque when electricity is applied
- Brief introduction of Xuzhou Jiulong Phoenix City
- How far is Danjiang International Hotel in Xichuan County from Gao Yi?
- Do you need a guarantor for a tourist visa in the United States?
- Where is a good place to hold a church wedding abroad?
- Introduction of Chongqing Great Wall Payment Card of Bank of China
- How about Anhui Huaao Biotechnology Co., Ltd.?
- How about Jinyi Holding Group Limited?