Traditional Culture Encyclopedia - Hotel accommodation - Installation spacing of u-shaped card of alc board

Installation spacing of u-shaped card of alc board

The installation spacing of U-shaped cards on alc plates is 600 mm. The U-shaped cards treated with special caulking agent at the gap should be arranged at the joint of two plates, and the distance between plates is 600 mm. U-shaped cards shall be derusted in advance and coated with antirust paint. When installing the rust-proof riser, first apply adhesive to the top and side of the plate, and then clip it into the U-shaped card at the top. After the bottom position is adjusted, it will be reinforced with a wooden wedge, and finally the flat-fell seam will be filled with ash. After the adhesive and the filling part at the end of the partition board meet the strength requirements, remove the wedge and repair the holes on the wedge.

Installation requirements of u-shaped card of alc board

ALC lightweight partition board must be typeset according to the modulus before installation, and ALC wallboard smaller than 200 shall not be typeset according to the principle of small board in the middle and large boards on both sides. After the installation, the water and electricity can be slotted 14 days. Slot and pay-off with professional tools first. After the installation of the post-slotted hydropower pipeline is completed, it is allowed to repair the anti-crack mortar at intervals of 7 days.