Traditional Culture Encyclopedia - Hotel franchise - What will happen if the water pump in the hotel breaks down?
What will happen if the water pump in the hotel breaks down?
Hotels generally have pipeline circulation pumps for air-conditioning water systems, high-rise water supply equipment and sewage pumps (some hotels have them).
Small submersible pump failures and troubleshooting
Troubleshooting methods
The motor does not rotate 1. The power supply voltage is too low 1. Avoid the peak power consumption
p>
2. The thin wire causes a large starting voltage drop 2. Replace the wire as required
3. The centrifugal switch fails or the capacitor is damaged 3. Adjust the centrifugal switch or replace the capacitor
4. Mechanical parts are stuck 4. Adjust the gap and clean, remove rust and remove oil
5. Burnt winding 5. Replace the winding
6. Cable segment 6. Replace the cable
7. The motor stops intermittently (the thermal protector operates) 7. Reduce the flow rate or mechanical resistance
8. Power outage 8. Check the cause of the power outage and eliminate the fault.
9. The water inlet wiring of the three-phase charging junction box is burned out 9. Disassemble the junction box and connect the broken wires
10. The cable is poorly connected to the control box 10. Restart Connection
11. The underwater cable joint is not tightly sealed or the cable sheath and core insulation layer are damaged. 11. Reconnect and replace the cable.
No water supply 1. Beyond the scope of use 1. Replace the pump that meets the requirements
2. The motor does not rotate 2. Check the reason why the motor does not rotate
3. The pump output water pipe joint is leaking 3. Reinstall it
Insufficient water supply 1. The pump is running beyond the head 1. Shorten the water outlet pipe or reduce the height of the water outlet
2. Impeller or filter Blockage 2. Clear debris
3. Decrease in speed caused by low voltage 3. Avoid peak power consumption
4. Wrong steering of three-phase motor 4. Replace any two-phase wiring position
5. The impeller is worn 5. Replace the impeller
The insulation resistance is low 1. The seal is damaged causing water to enter the motor 1. Replace the seal
2. Cable or The winding is damaged 2. Replace the cable, replace the winding.
3. Water enters the cable joint 3. Reconnect the joint
High noise 1. The bearing is damaged 1. Replace the bearing
Agricultural water pump faults and troubleshooting
Troubleshooting methods for the causes of faults
The water pump does not produce water
Or the water production is insufficient 1. The air in the pump cavity or suction pipe is not Drain 1. Fill the hand exhaust pump with water, move the pressure handle up and down, and drain the air in the pump chamber and suction pipeline.
2. Air leakage in the suction pipeline or hand exhaust pump 2. Check the water suction pipeline (including the hand-operated exhaust pump) and seal it
3. The water pump runs with excessive head 3. Reduce the head
4. The pump shaft speed is not enough 4. Increase the pump speed to Rated speed
5. The seal is damaged 5. Replace the seal
6. The water level is low 6. Reduce the installation height of the pump
7. Self-priming pump The amount of water injected is small or there is no water in the leakage. 7. Fill the pump cavity with water, or ensure that the pump cavity and water suction pipeline do not leak.
The water pump bearing is overheated. 1. Insufficient or no lubricating oil. 1. Add more water. Lubricating oil
2. The bearings are seriously worn or damaged 2. Replace the bearings
The internal combustion engine emits black smoke 1. The flow rate is too large or the lift is too low 1. Reduce the flow rate or increase the lift
p>2. The power of the internal combustion engine is not enough 2. Replace the internal combustion engine
Water comes out after stopping the pump
There is no water in the pipeline 1. The valve plate of the water outlet valve is damaged 1. Replace the valve plate< /p>
Micropump faults and troubleshooting
Troubleshooting methods for fault phenomena
Not starting 1. Low voltage 1. Replace copper core wires with more than 2 square meters and shorten the wires as much as possible Length
Cannot absorb water 1. The suction pipe is leaking 1. Check the joint and make sure it is sealed.
2. The seal is leaking 2. Replace the seal
3. The water level is low 3. Reduce the installation height of the pump
4. The gas in the pump chamber is not drained 4. Refill water and exhaust
Insufficient flow 1. Low water level 1. Reduce the height of the pump installation
2. The outlet pipe is too long 2. Shorten the outlet pipe
3. The pipeline is clogged 3. Clear foreign matter (including impeller)
4. Low voltage 4. Replace the thick wire (same as above)
The motor stops intermittently 1. The voltage is low 1. Replace Thick wires (same as above)
Pipeline pump tea stove pump faults and troubleshooting
Troubleshooting methods for causes of faults
Motor stops 1. Low voltage 1. Avoid using Electricity peak
2. The centrifugal switch fails 2. Adjust the centrifugal switch
3. The wire is thin, resulting in a large starting voltage drop. 3. Replace more than 2 square meters of wire
4. Mechanical parts are stuck. 4. Adjust the gap, clean, remove rust and remove oil.
5. Capacitor breakdown 5. Replace new capacitor
6. The circuit is not connected 6. Check the wires and connect the circuit
The pump does not produce water 1. There is air in the pump cavity that has not been removed. 1. The pump cavity is filled with water and the air is removed
2. The suction pipe is leaking. 2. Check the joint water valve to make it sealed
3. Inside the pump The seal is leaking 3. Adjust and replace the seal
4. The water pressure in the outlet pipe is too high 4. Reduce the pressure in the outlet pipe (unscrew the water valve)
The motor stops overheating 1. Voltage Too low 1. Adjust the voltage or avoid peak power consumption
2. Motor overload (large friction resistance, large flow) 2. Reduce mechanical friction or reduce flow
Insufficient flow 1. Partial blockage 1. Remove foreign matter
2. Large resistance loss in the pipeline 2. Shorten the pipeline and change the hard bend of the pipeline
3. The water temperature is too high or the pressure in the outlet pipe is too high High 3. Reduce the water temperature or the pressure in the outlet pipe
4. The opening of the water valve on the pipeline is insufficient 4. Unscrew the water valve
Self-priming pump faults and troubleshooting
Troubleshooting methods
The motor does not start 1. The circuit is blocked 1. Check the wires
2. The mechanical parts are stuck 2. Clear the obstacles
3. The voltage is too low 3. Avoid the peak electricity consumption
4. The wires are thin 4. Replace the copper core wires with more than 2 square millimeters
Cannot absorb water 1. The water suction pipe leaks 1 .Find the leaking part and seal it
2. The water level is lower than the pump suction lift 2. Reduce the installation height of the pump
3. The pump cavity is short of water 3. Open the water filling plug and drain the pump Fill the cavity with water
Open the faucet
Water does not come out immediately 1. Check valve leaks 1. Disassemble the valve and check whether there is any foreign matter stuck or the focus pad is deformed, the nut is loose, etc.
When the faucet is turned on, the water continues to flow out
and the pressure switch does not turn on
or operates frequently
. 1. The pipeline pressure fluctuates, is unstable, and is higher than the switch set pressure, causing the switch to disconnect. 1. Increase the set pressure of the pressure switch appropriately, cut off the power first, remove the transparent cover, and use a screwdriver to turn it in the "+" direction.
2. Open the faucet to reduce the water flow resistance.
Turn off the faucet power
The machine does not stop or turns on and off
Frequent movements
The pipeline pressure fluctuates and is lower than the switch setting pressure , there is no guarantee that the switch is completely disconnected. 1. Check whether the water outlet pipe and faucet are leaking
2. Check whether the pressure tank is leaking
3. Check whether the check valve is leaking
4. Lower the switch pressure value appropriately, cut off the power first, remove the transparent cover, and use a screwdriver to turn it in the direction of the "+" sign.
- Related articles
- Which bus should I take at karis Hotel in Yanta District?
- How about Danhua health chair? Danhua health chair price
- Is Wen Yuan apartment Xianyang or Xi's?
- The smallest dinosaur egg was found in Japan. What do you know about dinosaurs?
- Dry pot method
- Shang Yi Hotel Telephone
- Who knows how far it is from Xiamen North to Crystal International, the main road around the island?
- What about Yizheng Runcheng Washing Co., Ltd.?
- Spanish Tourism (9) Barcelona Port Area
- Brief introduction of Weihai Sunshine Building Hotel