The hotel's fire protection facilities and equipment mainly include:
1. Water fire extinguishing system (water pump, pool, water tank, pressure stabilizing device, water pump combiner, water supply pipe network and nozzles, fire hydrant, Control valve, terminal water test, etc.).
2. Emergency lighting system (dual power supply box or EPS power supply, emergency lighting box, emergency lights, evacuation sign lights, safety exits).
3. Automatic fire alarm system (composed of fire alarm host, detector, manual alarm, module, etc.).
4. Smoke prevention and exhaust system (pressurization, smoke exhaust fan, fire damper, pressurization, smoke exhaust port and pipeline).
5. Building fire protection and smoke protection zones (fire doors, fire shutter doors, fire windows, smoke-proof hanging walls and fire walls).
6. Evacuation (fire exits, evacuation stairs, fire elevator front room, outdoor fire lanes, fire rescue elevated sites, etc.).
7. Fire extinguishing equipment (fire extinguishers, rescue kits, fire-proof clothing, etc.).
Extended information:
Care and maintenance of fire protection facilities:
1. Since outdoor fire hydrants are outdoors, they are often damaged by nature and man-made damage, so they must be Maintain regularly.
2. The indoor fire hydrant water supply system must be comprehensively inspected at least every six months.
3. For automatic sprinkler fire extinguishing systems, the water flow indicator should be functionally tested every two months, and the alarm valve should be functionally tested every quarter.
4. The fire water pump is the heart of the water fire protection system, so it should be started and operated once a month to check whether the water pump is operating normally and whether the outlet water pressure reaches the design specified value. A simulated fire alarm linkage test should be conducted on the water fire protection system every year to test whether the water fire protection system is quickly activated and put into fire-fighting operations when a fire occurs.
5. For high- and low-expansion foam fire extinguishing systems, the foam liquid and its reservoir, filter, and related devices that generate foam should be inspected every six months. Underground pipelines should be inspected at least once every five years.
6. The gas fire extinguishing system should be inspected at least once a year, and the automatic detection and alarm system should be inspected at least twice a year.
7. Two years after the automatic fire alarm system is put into operation, all point-type temperature and smoke detectors should be cleaned by a specialized cleaning unit every three years. After cleaning, the response threshold and Other necessary functional tests, if it fails, it is strictly prohibited to reinstall and use it.
Baidu Encyclopedia-Firefighting Facilities
- Previous article:Have Guiyang Hu Quan Park and Vienna Hotel opened?
- Next article:What zodiac sign does the pig conflict with?
- Related articles
- What hotels or guesthouses are around 400 and around 500 yuan in Baiyun District?
- What is Dominica like?
- I want to take a one-day or two-day trip to Meizhou Island. I heard that people there are very dark. Seek raiders. Refuse to copy.
- How to get to Beijing Tianxinliang Hotel from Beijing Airport?
- What do you recommend for your graduation trip? It doesn't cost too much.
- Remittance and Residence Conditions in Jing Rong, Chengdu
- How to get from Kuala Lumpur airport to KLsentral and how long it will take; How can KLsentral get to Huaduya Station? How long will it take?
- How to take a bus from Guangzhou to Kaiping?
- General situation of Guangdong hot spring hotel
- What are the characteristics of private cuisine?