Traditional Culture Encyclopedia - Photography major - Precise layout of local floor and detailed drawing of wall reinforcement

Precise layout of local floor and detailed drawing of wall reinforcement

This paper will introduce the precise layout of local floors and the reinforcement details of walls. These drawings show important details of the building structure and need special attention.

Precise layout of falling plate

The figure on the left shows the exact layout of local floors. Plate thickness 150mm, plate elevation 20.850. It should be noted that the correct elevation should be 20.050, which is an important detail and needs special attention.

Wall reinforcement detail drawing

The picture on the right shows the details of wall reinforcement, and you can refer to the 3# details in this drawing. The wall is 200mm thick and goes deep into the ground beam. Φ 8 @150 indicates the vertical reinforcement arrangement inside and outside the concrete wall, and12 indicates the circumferential reinforcement inside and outside the concrete wall, although only 10 is shown in the figure. In addition, φ6 @ 450 is the reinforcement arrangement of the tractor. It should be emphasized that all steel bars are HRB400 grade.

Two questions

Finally, we need to pay attention to two problems in the drawing: one is the elevation, and the other is the number of 12 φ 12 steel bars. I suggest you communicate with the designer in time to ensure the accuracy of all details.