Does general fire protection include sprinkler system?

Although your formulation is a bit irregular, the meaning is generally correct. And this answer to the question is still very meaningful.

Except for some places in the specification that are not suitable for water spraying, it can be sprayed in other places (including automatic fire extinguishing system and rain spraying system with high requirements). The places listed in the following three specifications must be done:

Code for Fire Protection Design of Buildings (GB 500 16—2006)

8.5. 1 The following places shall be equipped with automatic fire extinguishing systems. Unless it is not suitable for waterproof or fire extinguishing and otherwise specified in this specification, automatic sprinkler system shall be adopted:

1 50000 spindle and above cotton mill opening and cleaning workshop; Classification carding workshop of linen mills with 5000 spindles and above; Dry, and screening match factory part; Pre-production, molding, slicing and embossing of foam plastic factory; Woodworking workshop covering an area of more than 1500m2; /kloc-Single-storey and multi-storey factories for shoes, clothing, toys and electronics with a total construction area of more than 0/500m2 or 3000m2; High-rise class C factory building; The preparation part of the aircraft engine test bed; Class C underground workshop with a building area of more than 500m2;

2 warehouses for cotton, wool, silk, hemp, chemical fiber, fur and its products with an area greater than 1000m2; Match warehouses with an area of over 600 square meters each; An empty mail bag warehouse with a construction area of more than 500 square meters in the postal building; Underground warehouse of combustible materials with a building area of more than 500m2; Elevated warehouses and high-rise warehouses for inflammable and flame-retardant articles (except cold storage);

3./kloc-a theater with more than 0/500 seats for special classes, classes 1 or other classes; A hall or auditorium with more than 2000 seats; A gymnasium with more than 3,000 seats; Lounge and equipment room for indoor staff in sports venues with more than 5,000 people;

4. Exhibition buildings, shops and hotels with a building area of more than 1500m2 or a total building area of more than 3000m2, as well as ward buildings, outpatient buildings and operating departments with the same building scale in hospitals; Underground shops with a building area of more than 500m2;

5. Central air conditioning system with return air duct (pipe), office building with a total construction area of more than 3000m2;

6 Underground, semi-underground, or more than four floors above the ground, or more than one, two or three floors of buildings, and the construction area of any floor is more than 300m2 (except swimming places);

7 libraries with more than 500,000 books.

8.5.3 The following places shall be equipped with rain shower system:

Potassium chlorate crushing workshop of match factory; Floor-area ratio lOOm2 is large, producing and using nitrocellulose, inkjet cotton, collodion, celluloid film and nitrocellulose;

2 warehouses of nitrocellulose, spray-painted cotton, collodion, celluloid film and nitrocellulose with a building area of more than 60 square meters or a storage capacity of more than 2t;

The bottling room and actual bottle warehouse of the LPG storage and distribution station where more than 3,000 bottles are bottled on the 3rd;

4.65,438+0,500-seat grand theater, first-class theater or other theaters and 2,000-seat auditorium;

5. Studios with a building area of over 400㎡ and film studios with a building area of over 500㎡;

6. Inspection parts for blank rolling, slicing, ball grinding and ball distribution in table tennis factory.

Code for fire protection design of high-rise civil buildings GB 50045-95 (2005 edition)

7.6. 1 excluding swimming pools, skating rinks and bathrooms with a building area of less than 5. Oom2, residential indoor rooms without central air conditioning, with Class A fire doors, parts unsuitable for fire fighting, high-rise buildings with building heights higher than looms and their podium buildings should be equipped with automatic sprinkler systems.

7.6.2 Except for swimming pools, skating rinks and bathrooms with a building area of less than 5. Oom2, ordinary houses, indoor rooms of houses with central air conditioning, parts unsuitable for water fire fighting, high-rise buildings with building height not exceeding loom and their podium should be equipped with automatic sprinkler system.

7.6.3 The following parts of Class II high-rise public buildings shall be equipped with automatic sprinkler systems:

7.6.3. 1 public * * * activity room;

7。 6.3.2 Walkways, offices and hotel rooms;

7.6.3.3 bottom of escalator;

7。 6.3.4 Flammable goods warehouse.

7.6.4 In high-rise buildings, song and dance entertainment places, air-conditioned rooms, public canteens, public kitchens, basements and semi-basements and other places where people often stay or there are many combustible materials, automatic sprinkler systems should be set up.

Code for fire protection design of garages, garages and parking lots (GB 50067-97)

7.2. 1 1, Class II and III above-ground garages, underground garages with more than 10 vehicles, mechanical three-dimensional garages or duplex garages, garages with vertical elevators as the vehicle evacuation exits, and industrial repair garages shall be equipped with automatic sprinkler systems.

Code for Fire Protection Design of Civil Air Defense Engineering GB 50098-98 (200 1 Edition)

7.3.2 The following civil air defense works and parts shall be equipped with automatic sprinkler system:

1 civil air defense works with a building area greater than 1000m2;

2. The audience hall of cinemas and auditoriums with more than 800 seats, the height from the lower surface of the ceiling to the audience floor shall not exceed 8 meters; When the use area of the stage is more than 200m2; The platform between the audience hall and the stage should be separated by fire curtain or water curtain;

3 use fire shutter instead of firewall or fire door. When the fire shutter does not meet the criteria for judging the fire resistance limit of the firewall, a closed automatic sprinkler system should be set on both sides of the fire shutter with a nozzle spacing of 2. Om, the distance between the nozzle and the shutter is 0.5m: water curtain protection can also be set when conditions permit;

4. Song and dance entertainment places and entertainment places;

There are 5 underground shops with a building area of over 500m2.