Traditional Culture Encyclopedia - Photography and portraiture - Why choose smart pet DR machine?
Why choose smart pet DR machine?
(1) Easy to use: Shanghai Jimmy high-end DR machine has established an integrated operating system based on the global unified multi-system control concept. The operating system covers all the work of X-ray photography on one working face, including patient data registration, preparation before exposure, exposure program selection, image measurement and post-processing, image printing and archiving, report making and so on. Low-end and mid-range DR manufacturers also adopt independent operating systems such as X-ray system parameter setting, exposure program selection and patient data registration, image measurement and image post-processing, image printing and archiving, and report production.
(2) Functional intelligence: Shanghai Jimmy smart pet? The most prominent feature of DR machine is automatic exposure control function as standard. According to the thickness, physiological and pathological characteristics of the subject, given an appropriate KV, the automatic exposure control function can accurately and automatically control the X-ray dose to obtain an appropriate exposure. When the sensing device receives enough X-ray dose, the device will automatically cut off the exposure to ensure a good image effect. With the application of automatic exposure control technology, pet doctors can quickly and skillfully use DR machines without rich clinical experience. In this way, the problem of repeated X-ray shooting caused by improper operation or low technology of doctors in some pet hospitals is effectively reduced, the X-ray dose accepted by medical staff and patients is greatly reduced, and the output of high-quality images also ensures the clinical diagnosis effect! !
(3) Rationality of configuration: Image quality is the simplest and most effective indicator of comprehensive performance of radiological imaging equipment. The quality of the image depends on the quality of the image chain. It is worth noting that the comprehensive performance of a device is not determined by the best components and parameters of the device, but by the worst components and lowest parameters. Just like a wooden barrel, how much water it can hold is not determined by the longest board, but by the shortest board. Therefore, when purchasing the whole DR machine, we should pay special attention to whether the worst components and the lowest parameters in the system can be used. In particular, it is necessary to prevent the phenomenon of big horse-drawn carts or small horse-drawn carts.
? (4) Quality service: To buy a good DR, besides the "hardware" of DR itself, we should also pay attention to whether the manufacturer has quality after-sales service. The life of a DR machine is generally 6-8 years, and the exposure times of the tube are 85,438+million times, which is a long journey. During the use period, only the manufacturer really locks the machine with a long-term "safety lock" and responds quickly in case of emergency, can the normal operation of the machine be guaranteed, and the pet doctor can really rest assured and avoid the situation that the machine is left unattended after being sold for 2 or 3 years. The engineer team of Shanghai Jimmy Company * is on standby 24 hours a day! !
Here I want to talk to you about the automatic exposure control system of intelligent pet DR machine:
The automatic exposure control system uses the X-ray sensor to detect the amount of rays passing through the illuminated object and reaching the flat panel detector, so as to control the exposure time of X-rays, which can make the X-ray images taken for different parts and different illuminated objects have the same exposure, and completely solve the problem of inconsistent X-ray exposure of the traditional DR machine.
So how does the automatic exposure control system work? Please see the following workflow of automatic exposure control system:
? 1.x-rays pass through the illuminated object and reach the automatic exposure machine.
? 2.? After receiving X-rays, the automatic exposure machine generates ionization signals.
? 3. The ionization signal is amplified and sent to the back end.
? 4.? Comparison between comparator of automatic exposure circuit and preset parameters
? 5. If the received X-ray dose has reached the requirements.
? 6.? The comparator of the automatic exposure circuit will send a signal to cut off the light bulb and the high voltage generator.
? 7. When the X-ray exposure is cut off, stop shooting.
Conventional DR machines usually require our pet doctors to adjust KV, mA and mA/s through calculation formulas, while Shanghai Jimmy's high-end automatic exposure DR machine only needs to adjust one parameter, and can shoot under the premise of correct positioning. Automatic exposure control system is used to accurately control the exposure time and exposure dose of X-rays! !
Image effect sharing
Pet DR machine inspection has become a routine inspection method in pet hospitals. As the director of a pet hospital said, "You can open a hospital without buying high-end color Doppler ultrasound, but you must never buy a DR machine". With the continuous popularization of DR products, especially in the era of rapid development of pet medical technology and service ability, we should use advanced equipment to serve pets. Shanghai Jimmy high-end automatic exposure DR machine is your best choice! !
- Previous article:100 sentence describes the beautiful copy on campus.
- Next article:Shenzhen moisture-proof cabinet brand
- Related articles
- How big is the film used for peony double reverse? Where do you usually buy 120 or 135? What movies have better effects?
- Jiajia is late. Artistic feature
- What are some good introductions to schools for graphic design?
- How many people used tickling and laughing to extract confessions during World War II?
- What is the price of wedding photos taken by Bojue Brigade?
- Glory 9 Huawei p 10 Which photo is better?
- Is Jiuchun’s old pumpkin delicious?
- Ask for some English translations that will be used when shooting with foreign models.
- Which talent network in Shenzhen publishes the best recruitment information? Kazuki Watanabe musician talent network has a carefree future, which one is better to recruit in Zhilian?
- What did Magic Blood 3, the Clock of Destiny, and the Scary Devil Mask 2 in Horror Street say?