Traditional Culture Encyclopedia - Hotel accommodation - What is the width of the hotel corridor?

What is the width of the hotel corridor?

The building is 24 meters high and belongs to a multi-storey building, so the provisions of the Code for Fire Protection Design of Buildings apply. According to Article 5.3. 14 of the Code, "Unless otherwise specified in this Code, the respective total widths of evacuation walkways, emergency exits, evacuation stairs and room evacuation doors in the building shall be determined by calculation. The clear width of emergency exits and room evacuation doors should not be less than 0.9m, and the clear width of evacuation walkways and stairs should not be less than1.1m; For apartment buildings with no more than 6 floors, when railings are set on one side of evacuation stairs, the minimum clear width should not be less than1.0m. "The minimum width of evacuation walkways in hotel buildings is required to be1.1m..

The minimum width of the evacuation walkway in civil buildings (including the small walkway in the door of the unit residence) is 2 strands according to the capacity.

The width of people flow. This is the minimum requirement to ensure safe evacuation, and it is also the minimum scale to meet the use requirements of other aspects.