Traditional Culture Encyclopedia - Hotel reservation - What does weak intelligence mean?
What does weak intelligence mean?
This has nothing to do with Jane. The first construction is mainly civil engineering. Roads and bridges. Electrical automation, etc.
Question 2: What does weak current mean? Weak current generally refers to direct current or audio line, video line, network line and telephone line, and the direct current voltage is generally within 24V. Telephone, computer, TV signal input (cable TV line), audio equipment (output line) and other electrical appliances in household appliances are all weak current electrical equipment.
Question 3: What is intelligent weak current engineering? Weak current engineering usually includes integrated wiring system, program-controlled exchange system, network system, TV system, monitoring system, parking lot management system, alarm system, building control system, information release system, patrol system and so on.
Question 4: What is weak intelligence? Intelligent building is an optimized modern new building integrating advanced technologies such as architecture, communication, computer network and monitoring. It has the characteristics of reasonable engineering investment, high degree of equipment automation control, scientific information management, high quality and efficiency service, flexible and convenient use, and safe and comfortable environment, and can meet the needs of the development of information society.
Question 5: What does intelligence mean? Weak electricity is relatively strong electricity. Conceptually, strong electricity and weak electricity are generally easy to distinguish. The main difference is the different uses. Strong electricity is used as power supply and weak electricity is used for information transmission. Specifically, it is roughly as follows:
(1) The AC frequency is different.
The frequency of strong electricity is generally 50Hz, which is called "power frequency", which means the frequency of industrial electricity. The frequency of weak current is often high frequency or ultra-high frequency, which is measured by KHz and MHz.
(2) Different transmission modes
Strong electricity is transmitted through transmission lines, and weak electricity is transmitted through wires or wireless. Radio is transmitted by electromagnetic waves.
(3) Power, voltage and current are different.
Strong electric power is measured in KW (kilowatt) and MW (megawatt), voltage is measured in V (volt) and KV (kilovolt), and current is measured in A (ampere) and kA (kiloampere); Weak current is measured in W (Watt) and mW (Milliwatt), voltage in V (Volt) and mV (Millivolt), and current in mA (mA) and uA (Microampere), so its circuit can be composed of printed circuit or integrated circuit.
Of course, there are also high-frequency (several hundred KHz) and intermediate-frequency devices in high voltage, but the voltage is higher and the current is larger. Another example is flashlights and electric razors. Although the voltage is very low, the power and current are very small, they are still strong. Due to the development of modern technology, weak current has penetrated into high voltage fields, such as power electronic devices and wireless remote control. But these can only be regarded as the weak current control part of high voltage, which is different from charged high voltage.
Question 6: What is the relationship between building intelligence and weak electricity? Intelligent building is the official name.
Weak electricity is a popular name among the people, as opposed to strong electricity.
Question 7: Introduction of weak current intelligent system. According to the national design code "Building Intelligent Design Standard" (GB503 14-2006), it is divided into six systems: intelligent integrated system (IIS), intelligent integrated system, information facility system (ITSI), information technology system and infrastructure. E Information Application System (ITAS) Information Technology Application System Building Equipment Management System (BMS) Building Management System Public Safety System (PSS) Public Safety System Electronic Equipment Factory Computer Room Engineering Each of the above categories contains different subsystems. According to the type and function of the building, the subsystems contained in the intelligent system are different.
Question 8: What are the aspects of weak current intelligence? This is for the hotel, depending on the actual needs of the building.
1, integrated wiring system;
2. Computer network and indoor Wifi coverage system; (Subcontracting designated by Party A)
3. Satellite TV and cable TV systems; (Subcontracting designated by Party A)
4. Voice communication system; (Subcontracting designated by Party A)
5. Smart card access control system;
6. Closed-circuit monitoring system;
7. Wireless patrol system;
8. Parking management system;
9, guest room intelligent control system (Party A's equipment, device installation, piping and auxiliary materials shall be the responsibility of Weak Current Company);
10, building intelligent control system;
1 1, public * * area intelligent dimming system;
12, UPS power supply, computer room engineering and lightning protection grounding system;
13, information publishing system;
14, room audio-visual entertainment system;
15, background music and emergency broadcasting system (excluding basements on floors 8 to 20 and public broadcasting system);
16, wireless intercom;
17, weak current integrated system (ibms);
18, intrusion alarm system
Question 9: What is the weak current intelligent building project? Building equipment monitoring system
This subsystem is very important, accounting for one-third of the design workload of all intelligent subsystems, and also closely cooperates with water, electricity, heating and other equipment majors. Its main description includes: design principles; The setting of mechanical and electrical equipment in this project, such as heating and cooling air conditioning units; Heat source boiler (water heater); Oil system; Ventilation equipment; Power transformation and distribution equipment; Water supply and drainage equipment; Lighting equipment, including public lighting, outdoor lighting, floodlighting, etc. ; Elevator, escalator, etc. ; Control requirements of each electromechanical equipment;
communications network system
The main contents include the setting principles of voice information points; List of information points of rooms with different functions on each floor (which can be the same as computer information points); Computer room setting; The equipment in the computer room shall be virtual switches and program-controlled switches; Access the network. If the integrated wiring system with the computer network system is not adopted, it is necessary to explain that communication cables are used for vertical pipelines and four-core communication lines are used for horizontal wiring. , each floor is equipped with telephone junction box; Pipeline laying mode: weak current shaft is used for vertical pipeline, and ceiling is used for horizontal pipeline. Some projects also include wireless communication systems.
Computer network system
The main content is the principle of setting up computer information points; List of information points of rooms with different functions on each floor (which can be the same as voice information points); Computer room setting; Setting of main network switch and floor network switch in computer network center room; Brief introduction of system manufacturer, brand, system situation and product performance. Some * * * office buildings should be equipped with external networks and internal networks, and some business departments should be equipped with small local area networks.
Structured integrated wiring system
Strictly speaking, the system is not an intelligent subsystem, but only the physical support of communication network system and computer network system. For the convenience of explanation, this paper also lists it as a subsystem. Some schemes design this system to replace communication network system and computer network system, which I think is inappropriate.
In current high-rise buildings, especially office buildings, wiring system is very important. Generally, it consists of work area, horizontal wiring, vertical wiring, floor equipment room and central computer room. In some projects, there are complex building subsystems between individual buildings. At present, there are more than 5 kinds of common wiring, more than 5 kinds of cables and information sockets, and 6 kinds of cables and modules are used in some projects, showing an upward trend. The vertical trunk line adopts optical fiber, and the incoming line generally adopts 6-core single-mode optical fiber. Ordinary 1000 m to single building, 100 m to floor or desktop.
Closed-circuit television monitoring and anti-theft alarm system
These are two interrelated subsystems belonging to the security system. It is necessary to list the setting list of monitoring points and anti-theft points in this project, and also introduce the manufacturers, brands and functions of the main equipment. At present, hard disk video technology is generally used for monitoring. Some projects need monitoring cameras and lighting linkage.
Satellite TV reception and cable TV system
The system generally adopts 860MHZ bidirectional adjacent frequency transmission system. For residential buildings, the centralized distribution branch system is generally adopted, and the original series branch method is basically not adopted.
Public address system
The system is generally compatible with the fire emergency broadcast system, and the switching mode with the fire emergency system should be explained. If the speaker settings are not exactly the same, it should be supplemented, and volume adjustment switches should be added in some places.
Parking lot management system
The system needs to be set up in large public building construction projects with underground parking lots. Set up a management room at the entrance and exit of the automobile passage to install the system host.
conference system
The general office building of conference rooms and lecture halls with various sizes and uses needs to be equipped with this system. Because the level and investment required by the construction unit are different, the content of the conference system is also different. There are mainly conference sound reinforcement, projection, camera system, conference video system, conference voting system, speech system and multilingual simultaneous interpretation system.
Large screen display system and touch multimedia information query system
The above two systems are generally set in offices and shopping malls of public construction projects, and the systems are set in public places such as foyer and lobby, which play the role of advertising and guidance to the public. A small control room should be set near the large screen display device with sufficient power supply. Generally, the area of 1 m2 is about 1KW.
Other systems
According to different buildings, there are comprehensive building intercom system, electronic patrol system, one-card access control, attendance and consumption system. If there is a shopping mall, there is also a POS system. ...& gt& gt
Question 10: What is weak current engineering? Weak current engineering is an intelligent building engineering. All electrical engineering except lighting and power consumption, such as intelligent automatic control system, automatic fire alarm system, television telephone and network communication system, entrance guard alarm control system, automatic toll collection system, security patrol monitoring system, computer management system, etc., are weak current engineering.
- Previous article:Zigong hotel statistics
- Next article:What are the disadvantages of Ctrip¡¯s independent travel package?
- Related articles
- How to get to Nakagawa Airport by Anning Airport Bus?
- Where is Qufu Home Inn?
- How to get to the Garden Expo Park Express Hotel from Yongding Road South?
- Is Jinshui Blue Bay in Wangqing County formal?
- Where is the exhibition hall of revolutionary historical sites of the Eastern Expedition Army?
- How about Di Chin Hotel in Yichang?
- Traffic around Guangzhou Garden Hotel
- Shuttle schedule of Xuzhou Guanyin airport
- Is Yihua Hot Spring Hotel in Conghua open?
- Which is cheaper, Fuzhou clothing wholesale market or Shishi clothing wholesale market?