Traditional Culture Encyclopedia - Weather forecast - What's wrong with Gree air conditioner e6?
What's wrong with Gree air conditioner e6?
(1) The motherboard of outdoor unit of Gree air conditioner is broken.
(2) The indoor and outdoor communication faults of Gree air conditioner mainly check whether the signal line is short-circuited or open-circuited.
(3) Conflict and protection of frequency conversion module of outdoor unit of Gree air conditioner.
(4) The fan motor of outdoor unit of Gree air conditioner is not energized or damaged.
(5) The main control circuit board of Gree air conditioner indoor unit is abnormal.
(6) The compressor of outdoor unit of Gree air conditioner is stopped by overload protection.
(7) The refrigeration system is blocked.
(8) Refrigerant (snow) leakage.
(9) The power supply voltage of the outdoor unit is insufficient.
2. Gree air conditioner e6- Gree air conditioner E6 solution:
(1) Replace the internal and external signal connection wires.
(2) If the fault still exists, please measure the power supply voltage of the signal port of the external board. If there is a voltage of 3.0V-5V, the communication is ok, and the fault should come from the frequency conversion motherboard or module.
(3) If the power supply voltage of the signal port of the external machine board is about 0V- 1V, it means that the control circuit board of the indoor machine is abnormal. Replace it and try again.
(4) If the outdoor frequency conversion module is very hot or the power supply voltage is abnormal, it means that there is something wrong with this module and it must be replaced with a new one.
(5) The outdoor fan rotates slowly or does not rotate when rotating, indicating that the outdoor fan is abnormal. Try the machine again after replacement.
(6) If the outdoor fan does not work, once the compressor is started, it will stop and display E6, indicating that the outdoor main control circuit board may not supply power to the outdoor fan. Please check SCR and relay or replace the motherboard of outdoor unit, and then try again.
Extended data:
Maintenance:
1, maintenance before startup
Usually, household air conditioners are turned off in September, turned on in May and June of the following year, and stopped for more than half a year. Therefore, a comprehensive "diagnosis" must be carried out before starting the air conditioner to check whether there is a "fault" in the air conditioner.
According to the inventory results, under the guidance of professional and technical personnel, do a good job of maintenance and cleaning, including the casing, fuselage and filter screen of outdoor and indoor units, and then start trial operation to observe the cooling speed and effect.
2. Maintenance during startup
After the air conditioner is turned on, it is necessary to determine the maintenance frequency during the start-up of the air conditioner according to various factors such as environmental conditions, climate conditions, start-up time, surrounding dust, air cleanliness, indoor cleanliness and so on. Poor environmental conditions, hot weather, outdated air conditioning, long start-up time of air conditioning, and increased maintenance times during air conditioning start-up, generally once a month and a half.
If the environmental conditions are good, the air conditioner is relatively new, there is less dust in the air, and the air conditioner can be turned on reasonably and can be used alternately with the electric fan, then the maintenance cycle can be extended appropriately, from air conditioner on to air conditioner off 1-2 times. Maintenance should be careful and meticulous, leaving no dead ends. Reach the standard, improve the cooling speed and effect, and achieve energy saving, freshness and comfort.
3. Maintenance after downtime
It is a perennial law to turn on the air conditioner when the weather gets warmer and turn off the air conditioner when the weather gets cooler. Pay attention to the comprehensive and detailed inspection of outdoor units and indoor units before the air conditioner is turned off. Maintenance, maintenance and cleaning should be linked one by one, and cannot be separated. Leaked links should be fixed and strictly checked.
References:
Xi An Gree Air Conditioning After-sales Maintenance Center Blog-Why does Gree Air Conditioning display E6?
References:
Baidu encyclopedia-air conditioning
- Previous article:What is a perpetual calendar?
- Next article:Appreciation of the Original and Translation of Liu Zongyuan's Liuzhou Dongman
- Related articles
- The weather in Weifang next week
- Four-day tour guide from Nanjing to Chengdu
- Does the painter's job have anything to do with the weather?
- Which city in Henan Province does Ruzhou belong to?
- Please refer to the attached figure for the use sequence of Korean cosmetics Whoo "Hou" brand Tianqidan series.
- What is the explanation of smog?
- Harbin jiangbei weather forecast
- How many kilometers is it from Shenyang to Lvjiang Village?
- Where is the hottest in winter in China?
- What is Qi in Qigong? Where is it? What are the meridians mentioned?