Traditional Culture Encyclopedia - Hotel franchise - What are the dimensions of hotel elevators? Hotel elevator safety management system

What are the dimensions of hotel elevators? Hotel elevator safety management system

With more and more high-rise buildings, elevators can be seen everywhere in our lives, but do you know what the size of the elevator is? The editor here will introduce to you the size of the hotel elevator. What is the size and the hotel elevator safety management system? I hope it can let everyone know more about the hotel elevator size and safety management system.

The dimensions of hotel elevator halls are regulated:

1. A smoke-proof front room, open balcony or alcove should be set up at the entrance of the stairwell. The smoke-proof front room can be shared with the front room of the fire elevator room;

2. The usable area of ??the front room: public buildings should not be less than 6.0m2, and residential buildings should not be less than 4.5m2; shared front rooms The use area: public buildings, high-rise factories and high-rise warehouses should not be less than 10.0m2, and residential buildings should not be less than 6.0m2;

3. The evacuation corridor leads to the front room and the front room leads to the stairs The door in the room should be a Class B fire door;

4. Except for the stairwell door and the front room door, there should be no other door or window openings on the interior walls of the smoke-proof stairwell and the front room (residential doors). (Except stairwell front room);

5. The first floor of the stairwell can include the walkway and foyer in the stairwell front room to form an enlarged smoke-proof front room, but Class B fire doors, etc. should be used Measures are separated from other aisles and rooms. The above are all mandatory rules! For details, please refer to the relevant provisions of Article 7.4.3 of the "Code for Fire Protection Design of Buildings".

What are the dimensions of hotel elevators:

Dimensions of hotel elevators 1. A smoke-proof front room, open balcony or alcove should be set up at the entrance of the stairwell. The smoke-proof front room can be shared with the front room of the fire elevator room;

Dimensions of hotel elevators 2. The use area of ??the front room: public buildings should not be less than 6.0m2, and residential buildings should not be less than 4.5m2; The usable area of ??the shared front room: public buildings, high-rise factories and high-rise warehouses should not be less than 10.0m2, and residential buildings should not be less than 6.0m2;

Dimensions of hotel elevators 3. Evacuation aisles leading to the front room And the door from the front room to the stairwell should use Class B fire doors;

Hotel elevator dimensions 4. In addition to the stairwell door and front room door, the smoke-proof stairwell and the interior walls of the front room No other door or window openings should be opened (except for the front room of the stairwell of the residence);

Hotel elevator safety management system

1. Elevator emergency handling procedures

1. If the elevator suddenly loses control and overspeeds and cannot be controlled, those with a driver should first cut off the power and press the button to stop the elevator on the nearest floor; the machine room attendant without a driver should immediately cut off the power after receiving the alarm and then use the intercom to greet the passengers to stay calm and Lift your heels and hold on to the car wall with your hands. Do not jump into the car.

2. If the elevator suddenly stops while driving, you should first cut off the power supply in the car, then use the intercom to comfort the passengers, and then manually level the car. Use the manual key to open the car door and release the passengers.

3. If electrical equipment burns, in addition to immediately cutting off the power supply and quickly notifying the fire center for rescue, 1211 and other gas fire extinguishers should be used to put out the fire.

4. If the door does not open at the parking floor, the personnel on duty in the machine room should first use the intercom to appease the passengers, ask which floor the car is parked on, and then use the manual key to open the car door as quickly as possible to release the passengers.

5. If there is water accumulation in the pit, the power supply should be cut off and the drainage should be checked immediately before it can be used.

6. If an accident occurs in the elevator, the personnel on duty in the machine room must stop immediately, organize relevant personnel to rescue the injured, protect the scene, and promptly report to the relevant departments for handling in accordance with the "three no-leaks" principle.

2. Elevator maintenance and inspection operating procedures

1. Is the elevator maintenance personnel performing maintenance on the elevator? nbsp;

2. During elevator maintenance and inspection, 36-volt running lights must be used.

3. When entering the computer room for maintenance work, you must first turn off the power switch, and do not repair the electrical control panel while the power is on to prevent electric shock accidents.

4. When entering the car top to add guide rail or car top sliding oil, the maintenance personnel must stand firm with both feet on the top of the car. When the car is running up and down, no part of the body should move. Go beyond the edge of the car to prevent injury.

5. When entering the pit of the shaft, effective measures must be taken to prevent the bridge car from suddenly falling.

6. Passengers and goods are not allowed during maintenance and inspection, but maintenance should not be carried out during peak passenger flow to avoid affecting business.

7. Elevator maintenance workers should inspect the mechanical and electrical equipment in the elevator machine room before each start of work; perform regular maintenance on the elevator and fill in the elevator equipment maintenance record card.

8. The reliability and correctness of operation of the main equipment of the elevator should be checked every week and necessary corrections and lubrication should be made.

9. After the elevator has been used for 3 months, the elevator maintenance worker should conduct a detailed inspection of the important mechanical and electrical equipment and repair the problems in a timely manner if any problems are found.

10. After the elevator is fully repaired every year, it should carefully rectify the rectification suggestions proposed by the Labor Bureau during the annual inspection and obtain the annual inspection certificate before it can continue to be used.

3. How to deal with people being locked in the hotel elevator car

1. Cut off the main power supply of the elevator first, and two people must cooperate in the operation.

2. Use special tools to release the brake manually.

3. Use the hand wheel in the machine room to make the elevator move up and down in a short distance.

4. There should be close cooperation between manual turning and manual opening of the brake, and the wheel should be turned to the standard position of the elevator leveling floor.

5. Open the elevator car door and send the guests out of the car safely.